05045497
roduct ID: 05045497 – Hydraulic Pressure Gauge (SL-IV & SL-V Series)
Description:
This component is a hydraulic pressure gauge, specifically designed for use on SL-IV and SL-V series waterjet intensifier pumps . It is a precision measurement instrument that displays the hydraulic system pressure, which is used to monitor the low-pressure hydraulic oil side of the intensifier. The gauge features a stainless steel case, safety glass, and glycerine filling, which dampens pointer vibration caused by pressure fluctuations in the hydraulic circuit .
The dial plate displays pressure in both bar and psi units, allowing operators to monitor system pressure in either measurement standard . This is an OEM replacement part for waterjet cutting systems.
Applications:
Used on SL-IV and SL-V series waterjet intensifier pumps to monitor hydraulic oil pressure
Installed on the hydraulic power unit or intensifier manifold, typically in line with the hydraulic pump outlet or control valve block
Enables operators to verify proper hydraulic system pressure for optimal intensifier performance
Assists in troubleshooting pressure-related issues, including pump cycling abnormalities and insufficient cutting pressure
Features:
Dual Scale Display: Dial plate calibrated in both bar and psi units for convenient pressure reading in either measurement standard
Stainless Steel Case: Corrosion-resistant housing suitable for harsh waterjet operating environments
Glycerine Filled: Dampens pointer vibration and pulsation from hydraulic pressure fluctuations, providing stable, readable gauge indications
Safety Glass: Protective window that withstands pressure spikes and provides operator protection in case of internal gauge failure
OEM Specification: Direct replacement part for SL-IV and SL-V series intensifier pumps
Maintenance:
Visual Inspection: Periodically inspect the gauge case and lens for signs of corrosion, cracking, or fluid leakage (glycerine seepage indicates seal failure)
Zero Check: With the hydraulic pump off and system pressure fully bled, verify the gauge needle returns to zero. A gauge that does not zero accurately requires replacement
Cleaning: Wipe the gauge exterior with a soft, damp cloth to remove hydraulic oil residue or abrasive dust; avoid using solvents that may damage the lens or case finish
Replacement Criteria: Replace the gauge if the lens is cracked, the case is corroded or damaged, the needle is bent or sticking, or if pressure readings are inconsistent with known system behavior
Pressure Verification: If gauge readings are suspect, verify against a calibrated master gauge during scheduled maintenance to ensure accuracy
Full Depressurization: Always fully depressurize both the hydraulic system and the high-pressure water system before removing or replacing the pressure gauge. Follow lockout/tagout procedures
Thread Sealant: When installing a replacement gauge, apply appropriate thread sealant to the connection threads to prevent hydraulic fluid leaks
Cross-Reference Information: This is an OEM replacement part for SL-IV and SL-V series pumps . Verify compatibility with your specific intensifier model before installation