05116017

Short Description:

Used for the SL-VI 100HP pump.
The company is a world-leading manufacturer of high-pressure waterjet pumps.
The SL-VI 100HP pump is a highly classic and popular industrial high-pressure pump.
We offer original accessories and professional technical support.


    
                  

Details

Product ID: 05116017 – High-Pressure Seal Repair Kit / Valve Service Kit

Description:
This component is a high-pressure seal repair kit or valve service kit for waterjet cutting equipment. It contains a collection of precision seals, O-rings, back-up rings, and related small parts required to service a specific high-pressure valve, cylinder, or intensifier component.

Applications:

  • Used to rebuild or service high-pressure water section components such as check valves, shut-off valves, pilot valves, or intensifier plunger seals.

  • Suitable for both pure water and abrasive waterjet systems.

  • Typically applied during scheduled preventive maintenance or when external leakage or pressure drop is observed.

Features:

  • Contains all necessary sealing elements for a specific repair procedure on a designated component.

  • Seals are manufactured from high-pressure-rated materials such as polyurethane, PTFE, or proprietary elastomers.

  • Precision-molded or machined to exact dimensions for proper fit and leak-free operation under extreme pressure.

  • Kit format reduces the need to source individual seal sizes separately, ensuring correct replacement parts are available.

Maintenance:

  • Refer to the equipment service manual to confirm this kit matches the specific valve or component requiring repair.

  • Fully depressurize the waterjet system and disconnect power before beginning any disassembly.

  • Carefully remove old seals, taking care not to scratch or damage sealing surfaces or bores.

  • Lubricate new seals with compatible high-pressure grease before installation as specified by the equipment manufacturer.

  • Replace all seals in the kit even if some appear undamaged; partial replacement may lead to premature failure.

  • Follow proper torque specifications and assembly sequence during reassembly.

  • After service, slowly pressurize the system and check for leaks before returning to full operation.